石墨消解火焰原子吸收法测定土壤中重金属
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

河北省科技支撑计划项目(13273802D);河北省教育厅科技计划项目(QN2014155)


Determination of heavy metals in soil by flame atomic absorption spectrometry using graphite digestion device
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    建立了石墨消解仪结合火焰原子吸收光谱仪测定土壤样品中铜、锌、镍、铬、锰5种元素的方法。经过对消解体系、样品消解量前处理条件进行优化,确定了最适合土壤消解的前处理步骤。各元素的检出限如下:Cu 0.62 mg/kg,Cr 0.48 mg/kg,Zn 0.45 mg/kg,Ni 0.53 mg/kg,Mn 0.50 mg/kg,回收率为96.5%~105%, 精密度为0.8%~2.0%。

    Abstract:

    This study established a method for determination of heavy metals such as Cu, Zn, Ni, Cr, and Mn in soil by flame atomic absorption spectrometry using graphite digestion device. A pretreatment process was confirmed after the pretreatment condition such as digestion system and amount of sample for digestion were optimized. The detection limits are 0.62,0.48,0.45,0.53 and 0.50 mg/kg for Cu, Cr, Zn, Ni and Mn, respectively. Recoveries are between 96.5% and 105%. RSD are between 0.8% and 2.0%.